Amorphous Alloy Three-Phase Oil Immersed Power Transformer is widely used in urban and rural power grid construction and renovation projects.

Product features:

1. Energy saving and consumption reduction: SH(B) 15-M amorphous alloy core oil immersed transformer compared with S11 transformer of the same capacity, the no-load loss decreases by about 60%, and the no-load current decreases by about 60%.

2. Enhanced ability to resist sudden short circuit: copper foil winding is adopted for low voltage, so that the electric field of the transformer is evenly distributed.The low voltage inner frame is made of formed cardboard tube, and the high voltage outer half stack is made of a layer by a layer of glass adhesive tape without weft. The laminated wood pad is used to strengthen the mechanical strength of the transformer.The transformer uses vacuum oil filling method to completely eliminate the bubbles in the coil, thus improving the transformer's ability to withstand sudden short circuit as a whole. 

3. The transformer connection group adopts Dyn11 to reduce the influence of harmonic on the power grid and improve the power supply quality. 

4. Tank rim uses stainless steel bolts, appearance is beautiful .

5. The oil tank adopts fully sealed oil tank to isolate transformer oil from air and slow down the aging of transformer oil.


Range of application:

The product is widely used in urban and rural power grid construction and renovation projects.The transformer can replace the transformer of silicon steel core and is widely used in outdoor distribution system.A large number of the product into the network operation can achieve good energy saving effect and reduce the air pollution.This product is especially suitable for the areas with insufficient electric power, large load fluctuation and difficulty in daily maintenance.Because the transformer adopts a fully sealed structure to avoid the contact between transformer oil and air, it can operate in the humid environment and is the ideal distribution equipment in the vast urban and rural distribution network.


Normal service condition:

1.The altitude shall not exceed 1000m;

2.Environment temperature: the highest temperature + 40 ℃; 

3.The highest average daily temperature +30 ℃; 

4.The highest annual average temperature +20 ℃; 

5.Outdoor lowest temperature -25 ℃;

6.Installation environment: the ground acceleration caused by the earthquake is ag<2m/s.

Note: please consult with our company to solve the problem beyond the normal environmental conditions. 


Technical parameters:

Type

Rated capacity

Voltage combination and Tapping range

Connection Symbol

No-load loss

Load loss

No-load current

Short circuit impedance

(kVA)

High-
voltage

Tapping range

Low-
voltage

W

W

%

%

SH15-M-30

30

6

6.3

10

10.5

11

±5%

or

±2×2.5%

0.4

Dyn11

33

630/600

1.50

4.0

SH15-M-50

50

43

910/870

1.20

SH15-M-63

63

50

1090/1040

1.10

SH15-M-80

80

60

1310/1250

1.00

SH15-M-100

100

75

1580/1500

0.9

SH15-M-125

125

85

1890/1800

0.8

SH15-M-160

160

100

2310/2200

0.6

SH15-M-200

200

120

2730/2600

0.6

SH15-M-250

250

140

3200/3050

0.6

SH15-M-315

315

170

3830/3650

0.5

SH15-M-400

400

200

4520/4300

0.5

SH15-M-500

500

40

5140/5150

0.5

SH15-M-630

630

320

6200

0.3

4.5

SH15-M-800

800

380

7500

0.3

SH15-M-1000

1000

450

10300

0.3

SH15-M-1250

1250

530

12000

0.2

SH15-M-1600

1600

630

14500

0.2

SH15-M-2000

2000

750

18300

0.2

5

SH15-M-2500

2500

900

21200

0.2


Type Meaning:

S: Three phase

(B): LV Foil winding (If none,means coil winding)

H: The core is an amorphous alloy magnetic material.

15 (or others): Performance level code.

M: Structural feature(M means whole sealing)

30(or others): Rated capacity kVA