Single Phase Oil Immersed Transformer

  • Single Phase Oil Immersed Transformer Manufacturers, Single Phase Oil Immersed Transformer Factory, Supply Single Phase Oil Immersed Transformer
Single Phase Oil Immersed Transformer
  • LOONG-TRANSFORMER ELECTRIC
  • JIANGSU CHINA
  • 30 DAYS
  • 1000SETS/MONTH

The transformer tanks are all cylindrical sealed structure, all transformers are grounded.

Normal standard configuration:

The transformer tanks are all cylindrical sealed structure, all transformers are grounded

Hooks and hooks, US standard mounting slings, pressure relief valves. One (or Two) high-pressure bushings are led out at the cover, and the low-pressure bushings are led out at the wall of the box.

There are bolted terminal blocks with holes. The high voltage tap changer should be turned off

In the case, follow the adjustment position indicated on the nameplate.


Full white protection standard configuration:

The transformer is fully self-protected and protects itself from lightning, short-circuit and overload.

The self-protection system can protect the transmission and distribution lines from failure of the transformer itself.

And causing power failure, its structural features are the same as ordinary ones, such as

Cylindrical fuel tank with hooks outside the box, installation of slings, grounding devices, nameplates,

First-class iron core and winding structure, with the following features and equipment:

One (or two) high-pressure bushings, which are led out from the cover, and the casing has a built-in current limiting fuse Breaker.

One (or two) arresters mounted on the wall of the box with the end close to the high pressure sleeve

The end of the tube is connected by a copper strip. a secondary disconnect switch is placed in the box,

The box wall is equipped with an operating handle, overload reset and signal light. Low pressure casing

At the wall of the box, X2 is equipped with a grounding device, and one end of the single sleeve passes through the high voltage bushing.

Lead out and ground the other end.


Application:

Rural power grids, remote mountainous areas, scattered villages, agricultural production, lighting and power

Electricity can also be used for energy-saving retrofit on-column distribution lines for railways and urban power grids. It can be operated in single-phase or three-phase single-phase as three-phase operation.


Normal Use Condition:

Altitude does not exceed 1000 meters

Ambient temperature: maximum temperature +40'C;

The highest daily average temperature: +30'C;

The highest annual average temperature: +20'C;

Outdoor minimum temperature: one 25'C

Installation environment: ground acceleration caused by earthquake is ag<2m/s


Technical parameters:

Rated Capacity

(kVA)

Voltage combination and tapping range


Connection Group

Short circuit impedance

(%)

No-load loss(W)

Load loss(W)

No-load current

High voltage (HV)

Tapping range of high voltage


Low voltage (LV)

5






28

130

4

10






44

230

3.5

16






52

320

3.2

20

A





64

380

3

30

6.3

±5

2x(0.22-0.24)



80

560

2.8

40

liO

Q C

100

690

2.5

50

10

or

or

Ii6

O.U

120

850

2.3

63

10.5

±2x2.5

0.22-0.24



144

1020

2.1

80

11





160

1260

2

100






192

1480

1.9

125






228

1750

1.8

160






292

2120

1.7


Capacity(kva)

5

10

16

20

30

40

50

63

80

100

125

160

Weight(kg)

Weight of Oil(kg)


22

25

30

35

65

70

80

80

95

105

120

150

Total Weight

80

100

125

140

205

250

280

320

380

435

510

615

External Dimension(mm)

L

530

530

530

560

610

660

660

660

690

690

720

760

W

440

440

440

470

610

660

760

860

895

935

960

1160

H

790

820

870

870

1060

1060

1080

1110

1180

1230

1280

1340

Installation Size(mm)

E1

330

330

330

360

410

460

460

460

496

496

524

560

E2

286

286

286

286

286

286

591

591

591

591

591

591